A major project has begun at the Salt Lake Temple in Salt Lake City, Utah, where extensive renovation and seismic strengthening work is underway. The work includes the installation of a base isolation system, strengthening of the existing masonry, and improvements to the building's structural and mechanical systems.
It should be noted that the temple was constructed between 1853 and 1893. It consists of large granite blocks supported by sandstone foundations. The foundations were constructed from sandstone obtained from City Creek Canyon, while the exterior walls were made of quartz monzonite. The floors were supported by steel girders, allowing longer spans and reducing the number of interior supports. Steel trusses were also used for the roof. In addition, the towers were made of stone.
Although the building has remained standing for more than 130 years, its masonry construction presents significant seismic vulnerabilities, particularly because of its proximity to the Wasatch fault. Following several years of structural assessments and feasibility studies, the Church of Jesus Christ of Latter-day Saints selected base isolation as the main approach for reducing earthquake demands on the building.
The project involved substantial work beneath and around the existing structure, including transferring the weight of the approximately 190-million-pound temple onto a new support system. Additional strengthening measures were also necessary to address the behavior of the masonry walls and towers under strong earthquake shaking.
The Church began evaluating the seismic vulnerability of its older buildings during the late 1990s and early 2000s. In 2005, Degenkolb Engineers conducted a seismic evaluation of the temple, while ARW Engineers carried out a structural assessment.
The studies identified the potential for sliding between masonry blocks during strong ground shaking, which could result in severe structural damage or collapse. Therefore, the decision was made to install a base isolation system to reduce the seismic forces transmitted to the building. This solution offered greater protection for both the structure and its occupants while reducing the need for extensive modifications to the historic masonry.
In addition, rather than relying only on code-prescribed earthquake motions, the design considered the effects of a magnitude 7.2 earthquake on the nearby Wasatch fault. The selected ground motion corresponded to the 84th-percentile shaking for this scenario and included high vertical accelerations.

Although base isolation was selected as the primary strengthening method, detailed dynamic analyses showed that it would not be sufficient on its own. The results indicated that vertical ground motion could produce significant horizontal oscillations in the masonry towers, increasing the possibility of sliding between individual stone blocks. Additional strengthening of the walls and towers was therefore included in the design. This involved vertical post-tensioning of the masonry, a post-tensioned steel framing system within the spires, and a new roof diaphragm connected to the towers and walls.
Moreover, a major part of the project involved installing a base isolation system beneath the existing temple. The building weighs approximately 190 million pounds (86 million kilograms) and is now supported by 98 Triple Pendulum isolators manufactured by Earthquake Protection Systems. The isolators allow controlled horizontal movement during an earthquake, reducing the seismic forces transmitted from the ground to the structure.
Installing the system beneath the existing masonry building required a carefully planned load-transfer procedure. New footings were constructed alongside the original stone foundations to support the temple during and after the transfer.
An important requirement was that the original foundations would remain beneath the building. The natural soil supporting the foundation stones also had to remain undisturbed until the loads had been transferred to the new support system. The transfer was carried out in a sequence intended to prevent significant movement or damage to the existing masonry. Once the building's weight had been transferred onto the new footings, excavation beneath the load-transfer system could proceed.
In addition to the structural work, the project included the replacement of the temple's mechanical, electrical, plumbing, and fire protection systems, along with accessibility improvements and upgrades to the surrounding areas. Specifically, the development included three new underground levels and two entrance pavilions north of the temple. Two visitor center buildings were also constructed to the south. The entrance pavilions provide additional access and space for temple functions but are not included in the base-isolated structural system.
Construction of the underground levels required excavation to approximately 45 feet (13.7 meters) below the existing temple foundations. Because of the depth and proximity of the excavation, extensive temporary shoring was necessary to maintain ground stability and limit settlement.
Furthermore, the high bearing pressures beneath the original foundations and new footings made the excavation particularly demanding. Engineers had to account for the effects of soil removal on the surrounding ground and the supporting structures. In order to address this problem, they installed temporary earth-retention systems, while geotechnical investigations and field monitoring were used to assess ground movements throughout construction.
Overall, the completed project is expected to significantly reduce the temple's vulnerability to major earthquakes along the Wasatch fault while preserving its original masonry construction and historic architectural features. The engineering methods used in the project may also provide useful experience for future seismic retrofits of large historic masonry buildings.
Sources: thechurchnews.com, structuremag.org, kmyu.tv
A University of Canterbury team, led by Civil and Natural Resources Engineering Professor Tim Sulli...
Structural systems refer to the arrangement of structural elements within a building or structure...
The new pedestrian tunnel connecting Grand Central Terminal with the No. 7 subway line at 42nd Stree...
Masonry structures have been used in historical buildings and continue to be used in contemporary...
A full-scale earthquake simulation carried out at the University of Auckland has shown that a newly...
The major concern that engineers and architects have when they design a new building is to ensure t...
The collapse of a four-story apartment building at 22 Alkminis Street in Athens’ Petralona neighborh...