The International Information Center for Structural Engineers

Wednesday, 08 January 2020 00:00cat

Keller 141 Harley Street underground project

Written by  TheStructuralEngineer.info
Minipiling at Harley Street, London Minipiling at Harley Street, London

Keller UK handled the design and construction of the 141 Harley Street project in London, UK.

Keller's specialist restricted access team designed and constructed a 73 linear meter secant piled retaining wall, a 35 linear meter contiguous piled retaining wall and load-bearing piles in limited space conditions. Thereby, the excavation of a three-story basement in central London to accommodate a new proton beam therapy facility was enabled.

Challenge and Solution

The project was challenging as the following limitations should be addressed:

  • Limited space on site and reduced access to the site via a residential cul-de-sac in central London.
  • Restrictions on noise, vibration and materials delivery times during the works.
  • Reduced headroom under the temporary props.
  • Strict pile tolerances and verticality to guarantee minimum space requirement at basement level 15m below.
  • Close proximity of the piles to neighboring buildings.

To tackle the situation Keller used the following solution. For the secant wall, two diesel-powered Klemm 709 rigs were used to install 117No up to 22m deep 508/450mm hard piles using case and auger methods and 117No 7m deep 450mm soft piles using SFA methods sealed into the London clay. Some wall sections required piles spacing as close as 550mm c/c to distribute and carry the heavy loads. For the contiguous wall, one CF3 type rig was lifted over the building and lowered into the basement to install 36No up to 15m deep 600mm piles and 12No up to 20m deep 600mm load bearing piles.

Source: Keller